国产18禁黄网站免费观看_WWW夜片内射视频日韩精品成人_国产在线观看成永久视频_WWW国产精品内射老师

橫河CW500

價(jià)格
電議

型號(hào)
CW500電能質(zhì)量分析儀

品牌
深圳市科瑞杰科技有限公司

所在地
暫無(wú)

更新時(shí)間
2019-03-15 05:55:06

瀏覽次數(shù)

    深圳市科瑞杰科技有限公司-YOKOGAWA日本橫河CW500電能質(zhì)量分析儀是一款使用安全電流鉗的現(xiàn)場(chǎng)功率測(cè)量?jī)x器,具有較高的可操作性,其功能已經(jīng)越了目前的CW240鉗式功率計(jì)。

     

     

    咨詢QQ281859292   2772057695

     

     深圳市科瑞杰科技有限公司

     

    橫河CW500電能質(zhì)量分析儀

     

     

    CW500_







     

    深圳市科瑞杰科技有限公司-YOKOGAWA日本橫河CW500電能質(zhì)量分析儀是一款使用安全電流鉗的現(xiàn)場(chǎng)功率測(cè)量?jī)x器,具有較高的可操作性,其功能已經(jīng)越了目前的CW240鉗式功率計(jì)。

     

     

     

    主要特性與技術(shù)指標(biāo)

     


    通過(guò)YOKOGAWA功率計(jì)可實(shí)現(xiàn)節(jié)能:

    功率的測(cè)量與記錄:

    • 一臺(tái)儀器即可實(shí)現(xiàn)電能分析和電能質(zhì)量控制同時(shí)測(cè)量3路電壓輸入

    • 2路直流電壓輸入

    • 4路電流探頭輸入

    • 瞬時(shí)/評(píng)價(jià)/大值/小值列表或電壓/電流/功率/功率因素/相位角/相位前電容計(jì)算


    支持用戶快速向?qū)Чδ埽?/span>

    • 測(cè)量前的檢測(cè)正確接線與設(shè)置

    • 自動(dòng)識(shí)別電流探頭類型

    • 可分別顯示電壓,電流的矢量相位差

     

     

    測(cè)量功能:

    • 臨時(shí)電力故障的測(cè)量

    • 連續(xù)電流故障測(cè)量

    • 諧波閃爍測(cè)試

    • 三相電路電壓、電流不平衡率測(cè)量

    • CW500Viewer可以PC通訊,可保存積分功率,電能質(zhì)量數(shù)據(jù),主要單元設(shè)置數(shù)據(jù)等

    • 可與外置SD內(nèi)存卡,USB通訊,藍(lán)牙通訊

    • 趨勢(shì)圖屏幕

     

     

    The Yokogawa CW500 is a portable power meter that utilizes current clamp-on probes, navigation screens and quick start guides to enable user friendly power consumption and power quality measurements in the field that conform to IEC6100-4-30 Class S. 

     

     

    FEATURES

     

    • Power Measurement and Logging

    • Power Quality Measurement

    • User Support

    • Analysis of Data and Report Generation

     

    Power Measuring and Logging

     

    • Simultaneously measures 3 CH Voltage input, 4 CH current clamp probe input, 2 CH DCV input.

    • Instantaneous/Average/Maximum/Minimum value list or trend graph screen of Voltage/ Current/Power/Power factor/Phase Angle/Phase Advanced Capacitance Calculation.

    • Integration Value of Active/ Reactive/Apparent Energy are each displayed for consumption and generation.

    • Demand monitoring which displays screens of present power consumption compared to aimed demand power values.

    CW500

     

     

    User Support

     

    Quick Start Guide Function:

     

    • The Quick Start Guide Function supports correct wiring and setting before measuring.

    • The Quick Start Guide Function automatically recognizes the type of current clamp probe.

     

    Vector Display:

    • The Vector Display indicates Voltage and Current phase difference and values between input channels of voltage and current.

    • The Vector Display checks whether the wiring is correct or not.

     

    Power Quality Measuring

     

    Measure Temporary Malfunctions of the Power Line

     

    • The CW500 captures temporary malfunction phenomena of the power line that can cause malfunction or destruction of devices due to voltage swell, voltage dip, interruption, transient voltage over, and inrush current by using a high sampling rate of 24 μs and RUS calculation.

    • Event data contains the type of malfunction, occurred time or occurrence finish time, measured value and waveform of voltage and current of all channels for approx. 200 ms period.

    • This measurement method conforms to IEC standard  61000- 4-30 Class S

     

    Measure Continuous Malfunction of the Power Line

     

    Harmonics

     

    • Measure and display graphs and lists of up to the 50th  Harmonic components of voltage, current, and power for each phase and total.

     

    Flicker

     

    • Measures 1-minute flicker (Pst, 1 min), short flicker, (Pst) and long flicker (Plt).

     

    Unbalance rate

     

    • Displays voltage and current unbalance rate on 3 phase wiring.

     

    CW500Viewer (Included PC software)

     

    • Automatically display the graphical and report data by clicking on the file on the PC display.

    • Manage multiple settings of the unit.

    • Measure in real-time using USB communication.

     

    Types of data

     

    • Integrated power data, power quality event data, main unit setting data, and screen capture data.

     

    Memory card and interface

     

    SD memory card, USB communication, Bluetooth communication (available for US, Canada and Japan only). 

     


     

    FUNCTIONS

     

    Power Measuring

     

    Power line and Input Channel: 3 CH Voltage, 4 CH for Current Clamp Probe.

     

    1P2W (up to 4 systems), 1P3W (up to 2 systems), 3P3W 2current (up to 2 systems), 3P3W 3current, 3P4W

     

    Power measuring item:

     

    Instantaneous, average, maximum, and minimum values for each setting period:

     

    Voltage/Current/Power (Active, Reactive, Apparent)/Power Factor/ Phase Angle/Frequency/Calculated Phase Shift Capacitance/DC voltage value 2 CH.

     

    Integration Value

     

    Energy (active, reactive, apparent), Demand (list or graph display of change in a specific period and as a whole)

     

    Recording Interval Period

     

    1/2/5/10/15/20/30 second, 1/2/5/10/15/20/30 minute, 1 hour/2 hours

     

    Recording method

     

    Manual, time, period

     

    Estimated Recording Length with 2 GB SD card

    CW500_Estimated_Recording_Leng

    • The recording length shortens according to the number of power quality events.

    • Only the included SD memory card or dedicated SD memory card is guaranteed.

     

    Various Measuring Screens

     

    List display, zoom display by 4 or 8 divisions, trend graph display, integration value display for energy, demand list display of value, demand graph display for change of period, demand graph display for whole recording

     

    List Display

     

    Items of measured values can be selected with the curser key.

    CW500_List_Display


     

    Zoom Display

     

    Zoom display can be selected by 4 or 8 divisions. 

    3

     

    Trend Graph

     

    Trend graph of voltage/ current/power/power factor/frequency/ advanced phase condenser external DC voltage.

    CW500_Trend_Graph

     

    Energy Display

     

    List of active, apparent, reactive by consumption or generation.

    CW500_Energy_Display

     

    Demand measuring

     

    Demand is the average power value of a specific period (usually 30 minutes). The contract with the power supplier conditionally concerns the maximum average power value between a period for the consumption fee. This function supports how to maintain within the target consumption by monitoring the estimated demand value to the setting rate with the maximum demand value.

     

    List of Demand Value

    CW500_List_of_Demand_Value

     

    Graph display of change on specific period

    CW500_Graph_Display_of_Change

     

    Graph display of whole demand trend

    CW500_Whole_demand_trend

     

     

    Analysis and Reporting of recorded data

     

    Analysis and reporting is enabled by simply clicking on the desired data on the software screen.

    Analysis can be viewed by trend graph, overage, maximum and minimum value of voltage current, power, and power factor. Report generating can be set daily by daytime, nighttime, working day, or off day. It can also be set on a monthly period d on daytime or nighttime, working day or off day. Additionally, energy data to quantify into crude oil barrels or CO2 can also be converted.

    Trend analysis graph

    CW500_Trend_Analysis_Graph

     

    Sample of report

    CW500_Sample_of_Report

     

    Power Quality Function

     

    Short period power line malfunctions such as voltage swells, dips, interruptions, transients, over or inrush currents, or long periods of harmonic distortion/flicker may damage or reset your devices.

     

    The CW500 helps to identify each of those short period malfunctions by recording occurrence time, occurrence finish time and waveforms. Additionally there is a digital output on occurrence.

     

    Long period malfunctions can be analyzed by harmonics, flicker, waveform, or by checking on the unbalance rate calculation for a 3 phase measurement.

     

    All data can be finalized into a report format with the included software. The CW500 conforms to the IEC standard of 61000-4-30 Class S.

    CW500_Table

     

     

    User Support Function 

     

    User Friendly

     

    Quick start guide and automatic type of clamp recognition

     

    The quick start guide will show on-start measuring and how to wire and set the range before measuring. The automatic clamp detection will insure the settings are correct.

     

    Start of guidance

     

    PUSH the “START/STOP” key.

    Select “Quick start guide”.

    Select recording item.

    CW500_Start_of_Guidance

     

    Wiring

     

    Select the wiring and the appropriate connection diagram will be displayed. 

    Connect accordingly.

    CW500_Wiring

     

    Wiring check/self diag./self id. 

     

    Wiring check, self-check and the type of clamp is automatically detected and the results displayed. 

    If NG is displayed, the detail can be confirmed by pressing the “ENTER” key.

    CW500_Wiring_Check

     

    Recording setting

     

    Set the recording interval time and the recording time or period.

    CW500_Recording_Setting

     

    Power supply from measuring line

     

    Power (under 240 VAC) can be supplied by using the power supply adapter  (sold separately).

    CW500_Example_Diagram_of_Power

    Note: This is not available for EV region.

     

    Leakage current measuring

     

    The external magnetic field effect is 0.002 A or less, at 400 A/.

    Yokogawa’s proprietary technology has achieved a magnetic field impact amount of 30 ppm even in adjacent power lines (at 100 A). 

    Below is an example of how to measure a neutral line of 3 phase 4 line.

    CW500_Leakage_current_measurin

     

    Multiple line measuring

     

    4 system load measuring

     

    Maximum of 4 systems are capable for 1 phase 2 line wiring.

    Maximum of 2 systems are capable for 1 phase 3 line or 3 phase 3 line wiring.

     

     

    SOFTWARE

     

    Software for Analysis and Setting (Free) CW500Viewer

     

    Data analysis, data reporting, making a setting file and doing a real time measurement can be easily done with the CW500Viewer.

     

    The data can be transferred by SD memory card, USB communication or Bluetooth communication (for USA, Canada, Japan only).

     

    The graph and lists are created by clicking on the data file.

     

    • The graph and lists of the recorded data file are created by clicking on the desired data file. They can be displayed and copied on a clipboard so it can be used on other software such as Word or Excel.

    • The time axis and measure axis can be zoomed in or out easily. With this capability, micro and macro changes can be displayed.

    • Waveforms of power quality events (Voltage swell, voltage dips, voltage interrupt, voltage transient, (over and inrush current) which are recorded by 200 ms period can be displayed and printed.

    • The integrated data can be added on one graph, enabling the whole energy integration data to be displayed.

    • Integrated energy data can be scaled into CO2 or the crude oil value.

    CW500_Graph_and_Lists

     

    Settings management

     

    • Setting data can be read out from and to the main unit via SD memory card, USB communication cable or Bluetooth communication (*1).

    • Setting data can be easily edited, saved and managed.

     

    Real time measurement

     

    • Real time measurement can be performed on up to 2 units simultaneously via USB communication or Bluetooth communication (*1)

     

    System Requirements

     

    CW500_System_Requirements

    CW500_multiple_graph_display

     

     

     

     

     

     

     

     

    橫河YOKOGAWA全球產(chǎn)品授權(quán)代理:

    深圳市科瑞杰科技有限公司

     undefined

     

    產(chǎn)品信息

     

    橫河YOKOGAWA

    功率計(jì):WT210/WT230/WT310/WT322/WT333/WT500/WT1800/WT3000-除WT500外均已停產(chǎn);

    升級(jí)版:WT310E/WT330E/WT310E/WT332E/WT333E/WT500/WT1800E/WT3000E.

    示波器:DLM2022/ DLM2024/DLM2032/ DLM2034/ DLM2052/ DLM2054/DLM4038/ DLM4058.

    數(shù)據(jù)采集器:MX100/MW100;

    新版:GM10.

    便攜式無(wú)紙記錄儀:MV1004/MV1006/MV1008/MV1012/MV1024/MV2008 MV2010/ MV2020/ MV2030/ MV2040/ MV2048-以上型號(hào)均已停產(chǎn);

    升級(jí)版:GP10/GP20.

    示波記錄儀:DL850/DL850V車輛版-均已停產(chǎn)

    升級(jí)版:DL850E/DL850EV.

     

    致茂chroma

    可編程直流電子負(fù)載:6310A/63200/6330A/63600

    LED電源測(cè)試直流電子負(fù)載:63110A/63113A

    可編程交流電子負(fù)載:63800

    可編程交流電源供應(yīng)器:61500/600

    可編程直流電源供應(yīng)器:62000P/62000H/62150H-600S/62000B/62000K

    電氣安規(guī)分析儀:19032/19032-P

     

     

    公司網(wǎng)址:

    WWW.KERUIJIE.CN

    WWW.KERUIJIE.COM.CN

     

    深圳公司:深圳市龍華新區(qū)建設(shè)路與東環(huán)一路交叉路口恒和大廈1204室

    :鄧女士

    :      

    華東辦事處:江蘇省丹陽(yáng)市中山路106號(hào)

    :羅先生

    :  

     

    以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),儀器儀表交易網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。
    溫馨提示:為規(guī)避購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

    其他推薦產(chǎn)品

    IT6108D大功率可編程直流電源
    IT6108D大功率可編
    電議
    DLM3034/DLM3022示波器
    DLM3034/DLM3
    電議
    DLM3022/DLM3054
    DLM3022/DLM3
    電議
    DLM3054/DLM3032示波器
    DLM3054/DLM3
    電議
    艾德克斯IT6012D-80-340
    艾德克斯IT6012D-
    電議
    艾德克斯IT6000C/IT6036C
    艾德克斯IT6000C/
    電議
    IT6000B回饋式源載系統(tǒng)
    IT6000B回饋式源載
    電議
    您是不是在找:
    萬(wàn)用表臺(tái)式萬(wàn)用表鉗型表兆歐表鹵素檢測(cè)儀多功能測(cè)試儀蓄電池檢測(cè)儀接地電阻測(cè)試儀功率分析儀電纜測(cè)高儀相序表微電阻計(jì)電橋電位差計(jì)電阻箱回路阻抗測(cè)試儀集成電路測(cè)試儀其他電工儀器電能質(zhì)量分析儀

    首頁(yè)| 關(guān)于我們| 聯(lián)系我們| 友情鏈接| 廣告服務(wù)| 會(huì)員服務(wù)| 付款方式| 意見(jiàn)反饋| 法律聲明| 服務(wù)條款